Preventing bacterial nosocominal infectious diseases caused by Pseudomonas aeruginosa, Legionella pneumophila, Stenotrophomonas maltophilia or Staphylococcus aureus among immunosuppressed and immunocompromised patients.
- Effective membrane filtration protecting against waterborne bacteria in dental treatment facilities
- Safe water hygiene
- High flow rate
- Up to 6 months operating time
- Easy filter change via push-fit quick-release coupling
Baclyser® IL DENT
The Baclyser® IL DENT hollow-fibre filter is specially used for in-line installation in the cold water supply to dental units. This disposable water filter is an inline, sterile filter with a 0.2 μm hollow-fibre membrane which displays retention of at least 7 log units1, thereby offering reliable protection of patients from infections by all critical water-borne germs such as legionella, pseudomonas, staphylococci or stenotrophomonas over a service life of up to 6 months and depending on the respective water quality.
The chemical composition of the water is not altered. The hygienic design and the use of bacteriostatic material in the housing prevent retrograde contamination incurred by splash water or physical contact. On expiry of the service life, the respective filter must be changed and disposed of in an environmentally-friendly manner via material recycling. This filter change is easy to complete thanks to the adapters.
An individual product marking on the product packaging guarantees traceability and facilitates the documentation process within the framework of hospital hygiene procedures.
1 Measured in accordance with the international ASTM F838-15a standard - Standard Test Method for Determining Bacterial Retention of Membrane Filters Utilized for Liquid Filtration.
Technical data
- Size: L 118 mm x ø 47 mm
- Bacteria Retention: 7 log steps B. diminuta
- Pore size: 0.2 μm (microfiltration)
- Operating time*: up to 6 months
- Chlorine resistance**: ≤ 10 ppm
- Flow rate: 13 l/min (at 5 bar, 20°C)
- Max. operating pressure: 5 bar
- Operating temperature: ≤ 40°C
- Connection: Push-fit quick-release coupling ø 8 mm
* The operating time is dependent on site specific water quality, the pressure ratios, the usage frequency and the required flow rate. ** Continuous dosage of ≤ 10 ppm over operating time; short-term (1h) high dosage (400,000 ppm h) for chemical disinfection.